IRIUS 3RW30 软起动器
SIRIUS 3RW30 基本性能型软起动器适合三相异步电机的软起动。
由于进行两相控制,不仅可将所有三相的电流在整个起动过程中保持在*小值,而且还消除了干扰性的直流成分。这不仅使得电机的两相起动高达 55 kW(400 V 时),也避免了如使用星-三角起动器产生的电流和转矩峰值。
SIRIUS 3RW30 基本性能型软起动器及其附件
|
|
|
|
|
3RW301. |
3RW302. |
3RW303. |
3RW304. |
3RW3003-2CB54 |
产品特性/功能 |
性能/优点 |
小型模块化设计 |
控制面板布局节约空间,安排清晰 |
使用电位器进行参数设置 |
调试简单而快速 |
集成在 SIRIUS 模块化系统中 |
各模块连接到电机起动保护器 |
混合开关装置和两相电机控制 |
通过避免直流分量,实现极低功耗和优化的电机控制 |
3RW30 软起动器可用于三相异步电机的软起动。
由于两相控制,在整个启动时间内,电流在各个相位始终保持在*小值。由于连续电压影响,在星形-三角形起动器条件下无可避免的现象,如电流和转矩峰值,在这种情况下不会发生。
请参见 PDF“软起动器选型助手”中“SIRIUS 3RW 软起动器”→“概述”下面的内容。
More information |
|
---|---|
Equipment Manual, see https://support.industry.siemens.com/cs/ww/en/view/38752095 |
Catalog LV 10, see www.siemens.com/lowvoltage/lv10 |
FAQs, see https://support.industry.siemens.com/cs/ww/en/ps/16213/faq |
|
Type |
|
3RW3013 |
3RW3014 |
3RW3016 |
3RW3017 |
3RW3018 |
---|---|---|---|---|---|---|
Power electronics |
||||||
Load rating rated operational current Ie |
|
|
||||
|
A |
3.6/3.3/3 |
6.5/6/5.5 |
9/8/7 |
12.5/12/11 |
17.6/17/14 |
Power loss |
|
|
||||
|
W |
0.25 |
0.5 |
1 |
2 |
4 |
|
W |
24 |
52 |
80 |
80 |
116 |
Permissible rated motor current and starts per hour |
|
|
||||
|
|
|
||||
|
A |
3.6/3.3 |
6.5/6.0 |
9/8 |
12.5/12.0 |
17.6/17.0 |
|
1/h |
200/150 |
87/60 |
50/50 |
85/70 |
62/46 |
|
A |
3.6/3.3 |
6.5/6.0 |
9/8 |
12.5/12.0 |
17.6/17.0 |
|
1/h |
150/100 |
64/46 |
35/35 |
62/47 |
45/32 |
1) Measurement at 60 °C according to UL/CSA not required.
2) At 300% IM, Tu = 40/50 °C.
3) For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone installation vertical. The quoted switching frequencies do not apply for automatic mode.
Type |
|
3RW3026 |
3RW3027 |
3RW3028 |
---|---|---|---|---|
Power electronics |
||||
Load rating rated operational current Ie |
|
|
||
|
A |
25.3/23/21 |
32.2/29/26 |
38/34/31 |
Power loss |
|
|
||
|
W |
8 |
13 |
19 |
|
W |
188 |
220 |
256 |
Permissible rated motor current and starts per hour |
|
|
||
|
|
|
||
|
A |
25/23 |
32/29 |
38/34 |
|
1/h |
23/23 |
23/23 |
19/19 |
|
A |
25/23 |
32/29 |
38/34 |
|
1/h |
15/15 |
16/16 |
12/12 |
1) Measurement at 60 °C according to UL/CSA not required.
2) At 300% IM, Tu = 40/50 °C.
3) For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone installation vertical. The quoted switching frequencies do not apply for automatic mode. Factors for permissible switching frequency with deviating mounting position, direct mounting, side-by-side mounting, see Equipment Manual in the chapter "Configuring".
Type |
|
3RW3036 |
3RW3037 |
3RW3038 |
3RW3046 |
3RW3047 |
---|---|---|---|---|---|---|
Power electronics |
||||||
Load rating rated operational current Ie |
|
|
||||
|
A |
45/42/39 |
65/58/53 |
72/62.1/60 |
80/73/66 |
106/98/90 |
Power loss |
|
|
||||
|
W |
6 |
12 |
15 |
12 |
21 |
|
W |
316 |
444 |
500 |
576 |
768 |
Permissible rated motor current and starts per hour |
|
|
||||
|
|
|
||||
|
A |
45/42 |
63/58 |
72/62 |
80/73 |
106/108 |
|
1/h |
38/38 |
23/23 |
22/22 |
22/22 |
15/15 |
|
A |
45/42 |
63/58 |
72/62 |
80/73 |
106/108 |
|
1/h |
26/26 |
15/15 |
15/15 |
15/15 |
10/10 |
1) Measurement at 60 °C according to UL/CSA not required.
2) At 300% IM, Tu = 40/50 °C.
3) For intermittent duty S4 with ON period = 30%, Tu = 40/50 °C, stand-alone installation vertical. The quoted switching frequencies do not apply for automatic mode.
Motor feeders according to IEC with 3RV2 motor starter protectors (without semiconductor protection)
Type of coordination "1", CLASS 10,
short-circuit breaking capacity Iq in kA, see table
Note:
For general recommendations on the setup of motor feeders with soft starters, see SIRIUS 3RW soft starters → Overview → Motor feeders with soft starters.
|
|
|
---|---|---|
Soft starters |
Motor starter protectors |
|
|
for 400 V systems |
|
Q11 |
Q1 |
I q |
Type |
Type |
kA |
Type of coordination "1" |
Standard (inline) circuit |
|
3RW3003 |
3RV2011-1EA10 |
50 |
3RW3013 |
3RV2011-1FA10 |
5 |
3RW3014 |
3RV2011-1HA10 |
5 |
3RW3016 |
3RV2011-1JA10 |
5 |
3RW3017 |
3RV2011-1KA10 |
5 |
3RW3018 |
3RV2021-4BA10 |
5 |
3RW3026 |
3RV2021-4DA10 |
55 |
3RW3027 |
3RV2021-4EA10 |
55 |
3RW3028 |
3RV2021-4FA10 |
55 |
3RW3036 |
3RV2031-4WA10 |
10 |
3RW3037 |
3RV2031-4JA10 |
10 |
3RW3038 |
3RV2031-4KA10 |
10 |
3RW3046 |
3RV2041-4RA10 |
11 |
3RW3047 |
3RV2041-4MA10 |
11 |
Note:
The specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller motor starter protectors/circuit breakers from the same series can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must match the connected three-phase motor, the short-circuit and overload requirements of the application, and the line protection for the cables used.
Motor feeders according to IEC with 3NA3 fuses
gG class full-range fuses for cable and line protection
according to IEC 60269‑2, without semiconductor protection
Type of coordination "1",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations on the setup of motor feeders with soft starters, see SIRIUS 3RW soft starters → Overview → Motor feeders with soft starters.
|
|
|
|
---|---|---|---|
Soft starters |
gG class fuse |
Line contactor (optional) |
|
|
for systems |
for systems |
for systems |
Q11 |
F1 |
Q21 |
Q21 |
Type |
Type |
Type |
Type |
Type of coordination "1" |
Standard (inline) circuit |
||
3RW3003 1) |
3NA38052) |
3RT2015 |
3RT2015 |
3RW3013 |
3NA3803-6 |
3RT2015 |
3RT2015 |
3RW3014 |
3NA3805-6 |
3RT2015 |
3RT2016 |
3RW3016 |
3NA3807-6 |
3RT2016 |
3RT2017 |
3RW3017 |
3NA3810-6 |
3RT2018 |
3RT2025 |
3RW3018 |
3NA3814-6 |
3RT2026 |
3RT2026 |
3RW3026 |
3NA3822-6 |
3RT2026 |
3RT2027 |
3RW3027 |
3NA3824-6 |
3RT2027 |
3RT2028 |
3RW3028 |
3NA3824-6 |
3RT2028 |
3RT2035 |
3RW3036 |
3NA3130-6 |
3RT2036 |
3RT2036 |
3RW3037 |
3NA3132-6 |
3RT2037 |
3RT2037 |
3RW3038 |
3NA3132-6 |
3RT2038 |
3RT2038 |
3RW3046 |
3NA3136-6 |
3RT2045 |
3RT2045 |
3RW3047 |
3NA3136-6 |
3RT2047 |
3RT2047 |
1) I q = 50 kA at 400 V.
2) 3NA3805‑1 (NH00), 5SB261 (DIAZED), 5SE2201‑6 (NEOZED).
Note:
The specified short-circuit breaking capacities Iq in kA are covered by combination tests. Smaller fuses than those specified can be used at any time as smaller ones trip more quickly in the event of a short circuit (unchanged short-circuit breaking capacity) and thus protect the soft starter in any case. The dimensioning of the short-circuit components must, however, be suitable for the connected three-phase motor and the line protection for the cables used.
Motor feeders according to IEC with 3NE1 SITOR fuses
gR/gS class full-range fuses for semiconductor protection,
cable and line protection (gS)
Type of coordination "2",
short-circuit breaking capacity Iq = 65 kA
Note:
For general recommendations on the setup of motor feeders with soft starters, see SIRIUS 3RW soft starters → Overview → Motor feeders with soft starters.
|
|
|
|
---|---|---|---|
Soft starters |
gR/gS class fuse |
Line contactor (optional) |
|
|
for systems |
for systems |
for systems |
Q11 |
F'1 |
Q21 |
Q21 |
Type |
Type |
Type |
Type |
Type of coordination "2" |
Standard (inline) circuit |
||
3RW3003 1) |
3NE1813-02) |
3RT2015 |
3RT2015 |
3RW3013 |
3NE1813-0 |
3RT2015 |
3RT2015 |
3RW3014 |
3NE1813-0 |
3RT2015 |
3RT2016 |
3RW3016 |
3NE1813-0 |
3RT2016 |
3RT2017 |
3RW3017 |
3NE1813-0 |
3RT2018 |
3RT2025 |
3RW3018 |
3NE1814-0 |
3RT2026 |
3RT2026 |
3RW3026 |
3NE1803-0 |
3RT2026 |
3RT2027 |
3RW3027 |
3NE1020-2 |
3RT2027 |
3RT2028 |
3RW3028 |
3NE1020-2 |
3RT2028 |
3RT2035 |
3RW3036 |
3NE1020-2 |
3RT2036 |
3RT2036 |
3RW3037 |
3NE1820-0 |
3RT2037 |
3RT2037 |
3RW3038 |
3NE1820-0 |
3RT2038 |
3RT2038 |
3RW3046 |
3NE1021-0 |
3RT2045 |
3RT2045 |
3RW3047 |
3NE1022-0 |
3RT2047 |
3RT2047 |
品牌: | 西门子 |
加工定制: | 是 |
型号: | 3RW3046-1BB14 |
用途: | 直接起动 |
额定电流: | 2 A |
额定电压: | 2 V |
适用电机: | 2 |
适用领域: | 电力工业 |