厂家直销天然气压缩机用10KV 1000KW高压电机固态软启动柜10KV,500KW,800KW,1200KW,1600KW,2000KW备有现货直接销售,高压固态软启动柜即晶闸管起动柜,在天然气压缩机起动过程中有效降低起动电流的作用,使空压机能够平滑平稳的起动,以下是针对10KV 1000KW高压固态软启动柜的相关参数做详细介绍;
基本参数Basic parameters(技术咨询热线: 乔经理) |
|
负载种类 Type of load |
三相高压鼠笼式异步电机、同步电机 Three-phase squirrel cageasynchronous andsynchronous motors |
交流电压 AC voltage |
3000---10000VAC |
工作频率 Service frequency |
50HZ/60HZ±2HZ |
相序 Phase sequence |
CMV允许在任何相序下工作(可通过参数设定) CMV is allowed to work with any phase sequence (through setting parameter) |
主回路组成 Composition of major loop |
(12SCRS、18SCRS、30SCRS视型号而定) (12SCRS、18SCRS、30SCRS depend on model) |
旁路接触器 Bypass contactor |
具有直接起动容量的接触器 Contactor with direct starting capacity |
控制电源 Control power |
AC220V±15% |
瞬时过电压保护 Transient voltage overload protection |
dv/dt吸收网络 dv/dt snubber network |
起动频次 Start frequency |
1—6次(每小时) 1-6 times per hour |
环境条件 Ambient condition |
环境温度:-20°C -+50°C Ambient temperature: -20°C -+50°C |
相对湿度:5%----95%无凝露 Relative humidity: 5%----95% no condensation |
|
海拔小于1500米(大于1500米需降容使用) Altitude less than 1500m (derating when altitude is more than 1500m) |
|
保护功能Protective functions |
|
缺相保护 Open-phase protection |
在起动或运行过程中,断开主电源的任意相 Cut off any phase of primary power supply in the course of starting or operation. |
运行过流保护 Over-current protection in operation |
运行过流保护设定:20~500%Ie Operational Over-current protection setting: 20~500%Ie |
相电流不平衡保护 Unbalanced phase current protection |
相电流不平衡保护:0~100% Unbalanced phase current protection: 0~100% |
过载保护 Overload protection |
过载保护级别:10A、10、15、20、25、30 Overload protection grade: 10A、10、15、20、25、30 |
欠载保护 Underload protection |
欠载保护级别:0~99% 欠载保护动作时间:0~250S Underload protection grade: 0~99% Action time of underload protection: 0~250S |
起动超时 Start timeout |
起动时间限制:0~120S Start time limit: 0~120S |
过压保护 Over-voltage protection |
主电源电压高于额定值的120%时,过压保护 When voltage of primary power supply is 120% higher than rated value, over-voltage protection is enabled. |
欠压保护 Under-voltage protection |
主电源电压低于额定值的70%时,欠压保护 When voltage of primary power supply is 70% lower than rated value, under-voltage protection is enabled. |
相序保护 Phase protection |
允许在任何相序下工作(可通过参数设定) Allow to work with any phase sequence (through setting parameter) |
接地保护 Ground protection |
接地电流大于设定值时保护 Protection available when grounding current is higher than set value |
通讯说明Description of communication |
|
通讯协议 Protocol |
Modbus RTU |
通讯接口 Communication interface |
RS485 |
网络连接 Network connection |
每台CMV可与32台CMV设备连网通讯 Each CMV can communicate with 32 CMV equipments in network. |
功能 Function |
通过通讯接口可以观察运行状态、编程 Operation state and programming can be observed through communication interface. |
操作界面Operating interface |
|
LCD显示 LCD display |
LCD(液晶)显示/触摸屏显示 LCD display/touch screen display |
语言 Language |
中、英文 Chinese and English |
键盘 Keyboard |
6个触摸式薄膜按键 6 touch membrane keyboard |
仪表显示Meter display |
|
主电源电压 Voltage of primary power supply |
显示三相主电源电压 Display voltage of three-phase primary power supply |
三相电流 Three-phase current |
显示三相主回路电流 Display current of three-phase major loop |
数据记录Data record |
|
故障记录 Fault history |
记录*近15次故障信息 Record recent 15 faults information |
起动次数记录 History of number of starts |
记录本装置的起动次数 Record number of starts of this soft starter |
奥东电气生产的ADGR系列高压固态软起动装置,主要适用于鼠笼式异步、同步电动机的起动和停止的控制与保护。它采用高质量串并联用晶闸管,无级控制输出电压、使电动机平稳地起动和停止。它具有过载、缺相、运行过流等故障保护功能,使用它能有效地避免因电动机起动电流过大给电网带来的有害冲击、能在有限的电网容量下正常使用大功率电机并延长其使用寿命。
高压固态软起动柜检测过程:
ADGR系列高压固态软起动装置特点:
1、采用高压功率晶闸管,组件式结构、模块化设计,便于安装维护。
2、具有多重过电压吸收、保护技术。
3、具备直接起动功能。在维修过程中即使发生故障,电机也可以采用直接起动方式工作,*大限度地延长运行时间。
4、采用32位ARM核微控制器执行中心控制,控制实时高效、显示直观、可靠性高、稳定性好。
5、采用高抗干扰性的数字式触发器与光纤隔离技术、使得装置的高、低压做到可靠的隔离。
6、中/英文液晶显示系统,操作界面人性化。
7、具有RS-485通讯接口,可与上位机或集中控制中心进行通信,Modbus/Profibus标准协议可选.
8、所有电路板均经过严格的老化实验。
奥东电气厂家直销天然气压缩机用10KV 1000KW高压电机固态软启动柜,还有其它规格,其它类型的软起动,如高压笼型水阻软起动,绕线软起动,高压磁控软起动柜,高压电抗软起动柜等,都是与压缩机配套的软起动,欢迎您来考察奥东电气高压固态软启动柜。
品牌: | 奥东电气 |
加工定制: | 是 |
型号: | ADGR |
用途: | 减压起动 |
额定电流: | 500 A |
额定电压: | 10000 V |
适用电机: | 鼠笼型电机 |
适用领域: | 石油化工;电力工业;冶金钢铁;城市建设 |